Aident logoAident logo centerAident Loadout
Use CasesPricingDocs
ENStart Now
AppsNgrok ToolsNgrok Replace Edge Route Circuit Breaker Module
Ngrok Tools

Ngrok Replace Edge Route Circuit Breaker Module

Replaces the circuit breaker module configuration on an HTTPS edge route. Circuit breakers protect upstream applications by rejecting traffic when error rates exceed thresholds, giving systems time to recover. Use this action when you need to configure or update circuit breaker…

Write actionRisk level 2 of 5API key connection
Use Ngrok Replace Edge Route Circuit Breaker Module

Pricing and limits

Aident logo

Product

Aident LoadoutAident Playbook EditorOpen-CUAK

About

AppsSkillsUse CasesDocsBlogPricingDownloadsPrivacy PolicyTerms of Service

Alternatives

vs Composiovs Zapier
llms.txtGet an AI summary of Aident LoadoutSummarize with ChatGPTSummarize with ClaudeSummarize with GeminiSummarize with Perplexity

© Aident Labs, 2024-2026

Pricing
Free
Unified payment
Not currently supported

Inputs

  • idstring
    Required
    The unique identifier of the route within the edge. This is the route whose circuit breaker module you want to replace. Starts with 'edghtsrt_' prefix.
  • edge_idstring
    Required
    The unique identifier of the HTTPS edge. This is the edge that contains the route you want to update. Starts with 'edghts_' prefix.
  • enabledboolean
    true if the module will be applied to traffic, false to disable. Default is true if unspecified.
  • num_bucketsinteger
    Integer number of buckets into which metrics are retained. Maximum value is 128.
  • rolling_windowinteger
    Integer number of seconds in the statistical rolling window that metrics are retained for.
  • tripped_durationinteger
    Integer number of seconds after the circuit is tripped to wait before re-evaluating upstream health.
  • volume_thresholdinteger
    Integer number of requests in a rolling window that will trip the circuit. Helpful if traffic volume is low.
  • error_threshold_percentagenumber
    Error threshold percentage between 0.0 and 1.0 (not 0-100). When upstream 5XX error rate exceeds this threshold, the circuit breaker will trip.

Observable output

  • data
    Required
    Data from the action execution
  • errorstring
    Error if any occurred during the execution of the action
  • successfulboolean
    Required
    Whether or not the action execution was successful or not

Skills that use this Action

Related use cases

No verified related use cases are linked yet.

Official source

Provider source

Skills that use this Action

No published Skills explicitly reference this Action yet.